Technical Specifications

The following table shows R-Values when Trufill is blown into a cavity at various densities. These values are indicitave and are based on standard timber frame construction.

Trufill Insulation System R-Value in Relation to Thickness

Nominal
Thickness (mm)
Open – 12 kg/m3
((0.043 W/mK at 15°C))
Low – 15 kg/m3
(0.041 W/mK at 15°C)
Medium – 19 kg/m3
(0.039 W/mK at 15°C)
High – 26 kg/m3
(0.035 W/mK at 15°C)
Ultra – 32 kg/m3
(0.0327 W/mK at 15°C)
45mm 1.0 1.0 1.1 1.2 1.37
90mm 2.0 2.1 2.3 2.5 2.75
140mm 3.2 3.4 3.5 4.0 4.28
175mm 4.0 4.2 4.4 5.0 5.35
190mm 4.4 4.6 4.8 5.4 5.81
225mm 5.2 5.4 5.7 6.4 6.88
240mm 5.5 5.8 6.1 6.8 7.33
275mm 6.3 6.7 7.0 7.8 8.40
290mm 6.7 7.0 7.4 8.2 8.86
325mm 7.5 7.9 8.3 9.2 9.93
360mm 8.3 8.7 9.2 10.2 11.00
395mm 9.1 9.6 10.1 11.2 12.07
Trufill Roof

Truss & Skillion Roofs

Skillion blown at low, medium, high or ultra density. Truss blown at open density only.

Trufill Roof

Internal & External Walls

Blown at medium, high or ultra density for higher performance.
Trufill Roof

Underfloor and Midfloor

Blown at all densities excluding open, depending on reqirements.

Resources

Trufill® provides excellent thermal performance due to a low thermal conductivity and a complete and consistent installation. Trufill® provides a choice of R-Values based on the installed thickness and installed weight per square metre. The stated thermal resistance (R-Value) is provided by installing the required density at the thickness (per the manufacturer’s instructions). Failure to install less than the required density and thickness will result in lower insulation R-Values.

Trufill Datasheet

If you’re after more information on how to install Trufill Insulation download our Installation Manual.
Trufill Codemark Certificate

The Trufill Insulation system is CodeMark certified. Download the CodeMark Certificate below.

Trufill Codemark Certificate

Trufill is now available on Masterspec (4710ST). View our work sections and documents here.

Trufill Codemark Certificate

If you’re an authorised installer you can request a copy of the Trufill Installation Manual below.


Additional Information

Trufill® provides excellent thermal performance due to a low thermal conductivity and a complete and consistent installation. Trufill® provides a choice of R-Values based on the installed thickness and installed weight per square metre. The stated thermal resistance (R-Value) is provided by installing the required density at the thickness (per the manufacturer’s instructions). Failure to install less than the required density and thickness will result in lower insulation R-Values.
Equipment required
To achieve the required R-Value, this product must be installed using an approved blowing machine and equipment. Installation must be complete inline with the system guidelines and by an Approved Installer.
Packaging
Trufill® is packaged in a strong, poly bag that offers excellent protection from abuse, dust and moisture. Knauf Insulation packages stack without slipping and are easy to handle and store.
Durability
– Non-combustible, non-corrosive.
– Will not rot, mildew or deteriorate.
– Will not sustain vermin.
– Will not settle.
– Consistent, reliable performance.
– Performs for the lifetime of the building.
Acoustic performance
Improves sound transmission class (STC) by between 4 and 10 points.
Thermal performance
Each bag contains a high percentage of recycled glass content. Carbon negative. When used as thermal insulation, Trufill® will recover the energy used to produce it within days of installation. It will continue to reduce carbon generation for as long as it is in place.
Engineered Blow-in Insulation System
Trufill® is an engineered solution which incorporates a system approach to the insulation of your ceiling space. A range of accessories are supplied with the System to provide a range of solutions and performance checks. Backed by the Approved Installer network, to provide confidence in the performance of the product.

New Zealand Building Code Compliance

Clause B2 DURABILITY: Performance B2,3,1(b) 15 years. Trufill® will meet this requirement.

Clause E3 INTERNAL MOISTURE: Performance E3.3.1. Trufill® will contribute to meeting this requirement.

Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Trufill® meets this requirement and will not present a health hazard to people.

Clause H1 ENERGY EFFICIENCY: Performance H1.3.1(a) and H1.3.2 E. Trufill® will contribute to meeting these requirements. Trufill® thermal resistance has been determined by AS/NZS 4859.1. Trufill® is an acceptable solution in terms of the New Zealand Building Code.